DQRID : D940616.3
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/03/1994120006/08/19941515Incorrect
more
Subject:
SGP/EBBR/E12 - Wind Direction
DataStreams:sgp5ebbrE12.b1, sgp30ebbrE12.b1, sgp15ebbrE12.b1
Description:
For much of the period above, a malfunction in the E12 EBBR wind direction
sensor (insect larvae shorting out the circuit board) caused incorrect
values for 5 minute res_ws, wind_d, and sigma_wd, 15 minute mv_wind_d, and
30 minute res_ws, wind_d, and sigma_wd.  Wind direction normally indicated
north (near 0 or 360 degrees); there were some times during the period when
wind directions looked good, but the lack of variation in direction and sigma
implies that the data is suspect.  Therefore, it would be wise to flag all
of the values listed above during the entire time period as incorrect.
The wind direction sensor (S/N 3081) was replaced with S/N 3042 at 1515 GMT
on June 8, 1994.
Suggestions: 
Resultant wind speed is incorrect: under this condition it has the same value as 

mean wind speed.
Measurements:sgp15ebbrE12.b1:
  • wdir_vec_mean_mv
more
sgp5ebbrE12.b1:
  • wspd_vec_mean
  • wdir_vec_mean
  • wdir_vec_std
more
sgp30ebbrE12.b1:
  • wspd_vec_mean
  • wdir_vec_mean
  • wdir_vec_std
more