DQRID : D940711.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/28/1994170006/29/19941700Incorrect
more
Subject:
SGP/EBBR/E7 - Reprocess: Soil Temperature Probe Failure
DataStreams:sgp30ebbrE7.b1, sgp15ebbrE7.b1
Description:
Failure of soil temperature probe #4 at E7, Elk Falls, KS resulted in incorrect
data values for 6 fields for the period of time listed above.  The soil
temperature value from probe #4 went offscale, resulting in a zero value
for the soil energy storage term calculated from that probe and thus no
contribution to the total soil heat flux for soils set 4 and the same for
average soil heat flux.  This led to incorrect sensible and latent heat
flux values.

The fields affected were:

30 minute: ts4, ces4, g4, ave_shf, e, h

15 minute: rr_ts4.
Suggestions: 
Measurements:sgp15ebbrE7.b1:
  • soil_temp_4_rr
more
sgp30ebbrE7.b1:
  • latent_heat_flux
  • surface_soil_heat_flux_avg
  • energy_storage_change_4
  • surface_soil_heat_flux_4
  • sensible_heat_flux
  • soil_temp_4
more

Close this window