Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/18/1995 | 1230 | 08/18/1995 | 1500 | Incorrect |
08/16/1995 | 0600 | 08/16/1995 | 1530 | Incorrect |
08/19/1995 | 1100 | 08/19/1995 | 1500 | Incorrect |
08/20/1995 | 0900 | 08/20/1995 | 1500 | Incorrect |
08/21/1995 | 0600 | 08/21/1995 | 1500 | Incorrect |
Subject: | SGP/EBBR/E13 - Battery Voltage Drop |
DataStreams: | sgp30ebbrE13.b1, sgp5ebbrE13.b1, sgp15ebbrE13.b1 |
Description: | Sometime before August 16, 1995 the AC/DC converter was switched off and the instrument heaters were switched on. The solar panel was not able to keep the battery voltage up under these conditions. Much of the data for the periods indicated is incorrect, especially data from the sensors that require 12 volts DC power. The data would have to be inspected to determine what data is correct and what is incorrect. It would be safest to exclude all data from those periods from any analysis. Site operations switched the heaters off and turned the converter back on on August 21, 1995. As reported in a recent DQR, the fluxes from the EBBR are incorrect presently because of a malfunctioning T/RH probe; no spares are presently available. |
Suggestions: | |
Measurements: | sgp15ebbrE13.b1: more
sgp5ebbrE13.b1: more sgp30ebbrE13.b1: more |