Subject:
SGP/EBBR/E26 - Right tair Offscale
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
Description:
On five days in January 1996 at E26, Cement, OK EBBR the right thermocouple
output went offscale.  The cause for this is unknown, although poor probe
connections are common.  Site Operation personnel tightened the probe
connections in mid January.

Five minute data would need to be inspected during the periods
indicated for incorrect five minute values.  Incorrect data for the period
indicated includes:

5 minute:   tair_top, tair_bot

15 minute:  tair_r

30 minute:  tair_top, tair_bot, bowen, h, e

The data are not recoverable from other measurements.