DQRID : D960122.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
01/18/1996053301/18/19960533Incorrect
more
Subject:
Jump in pressure value upon launch
DataStreams:sgpsondewrpnC1.a1, sgpsondewrpnC1.a0
Description:
It appears that the pressure sensor was jarred during launch and jumped readings from 
973.1 hPa at the surface to 960.7 hPa at the first sample after launch.  This results in 
erroneous altitude values throughout the sounding and erroneous ascent rate values during the 
first 30 seconds. The relative altitude calculations after the second sample should be 
correct.  The surface winds were quite strong, 16.5 m/s.  The bouncing of the balloon 
during the launch might account for the abnormal jarring of the sonde.
Suggestions: 
Measurements:sgpsondewrpnC1.a0:
  • asc
  • pres
more
sgpsondewrpnC1.a1:
  • asc
  • pres
more