DQRID : D000210.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/11/1999000006/29/19992145Incorrect
more
Subject:
SGP/EBBR/E26 - Temperature from Left T/RH Probe Incorrect
DataStreams:sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
The temperature from the left T/RH probe went offscale frequently.  This
temperature is used in the calculation of the vapor pressure.  Therefore,
top and bottom Thum measurements, left Thum, top and bottom vapor pressure 
measurements, vapor pressure gradients, and the resulting latent and 
sensible heat fluxes and bowen ratio were frequently incorrect for the 
period stated.
Suggestions: 
Measurements:sgp5ebbrE26.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_trh_top
  • temp_trh_bottom
more
sgp15ebbrE26.b1:
  • temp_trh_left_rr
more
sgp30ebbrE26.b1:
  • vapor_pressure_top
  • bowen_ratio
  • temp_trh_top
  • sensible_heat_flux
  • latent_heat_flux
  • vapor_pressure_bottom
  • temp_trh_bottom
more

Close this window