Description: | something, since the problem began during J-panel changeout the 4/7/99 PM.
At the 7/21/99 PM, the reference temperature was repaired and reseated. At
that time the SHF #5 data became correct again; the two events are probably
related only in that other connections, including that of the SHF #5, were
probably reseated at the same time. The report of the PM activity is not
detailed enough to determine the exact causes and fixes.
The incorrect SHF #5 data can be identified by it being an order of
magnitude larger than the values from the other soil heat flow sensors.
Affected data are:
5 minute: none
15 minute: mv_hft5
30 minute: shf5, c_shf5, g5, ave_shf, e, h |