DQRID : D000211.12
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/18/1999171506/18/19991745Incorrect
more
Subject:
SGP/EBBR - EBBR E20 Thermocouple Data Incorrect
DataStreams:sgp5ebbrE20.b1, sgp30ebbrE20.b1, sgp15ebbrE20.b1
Description:
Left and right thermocouple air temperature data are incorrect during the
replacement of the right thermocouple.

Affected data are:

5 minute:  tair_bot, tair_top
15 minute: tai_r, tair_l
30 minute: tair_bot, tair_top, e, h, bowen
Suggestions: 
Measurements:sgp30ebbrE20.b1:
  • bowen_ratio
  • temp_air_top
  • temp_air_bottom
  • latent_heat_flux
  • sensible_heat_flux
more
sgp15ebbrE20.b1:
  • temp_air_left
  • temp_air_right
more
sgp5ebbrE20.b1:
  • temp_air_top
  • temp_air_bottom
more

Close this window