DQRID : D000301.9
Start DateStart TimeEnd DateEnd Time Data Quality Metric
09/25/1999070010/07/19991700Incorrect
more
Subject:
SGP/EBBR/E26 - Net Radiation Incorrect
DataStreams:sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1
Description:
The net radiometer top dome was broken and water had entered.  Net 
radiation values are therefore incorrect during the period.

The affected data are:

5 minute:  q
15 minute: mv_q
30 minute: q, h, e
Suggestions: 
Measurements:sgp5ebbrE26.b1:
  • net_radiation
more
sgp15ebbrE26.b1:
  • net_radiation_mv
more
sgp30ebbrE26.b1:
  • sensible_heat_flux
  • latent_heat_flux
  • net_radiation
more

Close this window