Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/01/1999 | 0000 | 10/31/1999 | 2359 | Does not affect quality |
Subject: | SGP/OKM Overview of Automated QA - October 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.b1, sgp15okmX1.b1, sgp15okmX1.a1, sgp05okmX1.a1, sgp15okmX1.00 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the October 1999 Oklahoma Mesonet data. There are a few special events in the October data Date Station Parameter(s) ---- ------- ------------ 10/02 TALI TAIR -| Strong low-level inversion caused many 10/13 CHEY TAIR | sites which "poked" into the warmer air 10/20 CHEY TAIR | to be spatially inconsistent with neigh- 10/20 MINC TAIR | boring stations. You can disregard the 10/26 CHEY TAIR -| flags for these stations. ======================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of October, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================= Notes: Over 375 trouble tickets were issued and reconciled during October-- mainly due to OASIS upgrades. Here's a summary of the tickets that directly affected our data quality. ======================================================================== TAIR Current: None Added: None Resolved: #3386 BEAV Replaced bad thermistor RELH Current: None Added: None Resolved: #3004 BREC Replaced bad sensor #3012 CHER Replaced sensor stuck at 0% #3385 BEAV Replaced bad sensor WDIR Current: None Added: None Resolved: #2711 HOOK Replaced sensor with suspicious direction WSPD Current: #2736 BBOW Sensor suspected of under-reporting during strong winds/severe weather Added: None Resolved: None PRES Current: None Added: None Resolved: None SRAD Current: #3361 ALTU Monthly QA indicates sensor is reporting ~50 W/m^2 low Added: None Resolved: #3387 BEAV Replaced sensor stuck at -30 #3680 EUFA Replaced sensor with low bias #3838 FTCB Re-leveled pyranometer RAIN Current: #3840 COPA Sensor reported 0.0 during heavy rain Added: None Resolved: #2681 BURB Replaced bad switch #3688 WILB Replaced bad switch TA9M Current: None Added: None Resolved: #3360 BREC Replaced bad thermistor WS2M Current: #3670 MEDI Sensor at improper height Added: None Resolved: #3392 PAUL Sensor moved to proper height TS10 Current: #3001 ADAX Stuck at less than -100.0 C #3003 HOBA Sensor biased 20 C warm #3019 FTCB Sensor reporting numerous observations below -100.0 C Added: None Resolved: #2260 BOWL Replaced sensor damaged by gophers #2673 BURB Replaced lightning-damaged sensor TB10 Current: None Added: None Resolved: #2864 FREE Replaced sensor stuck at -73 C TS05 Current: #2604 HOBA Sensor stuck at -273.1 C Added: None Resolved: #3359 WYNO Suspicious sensor tested ok by tech TB05 Current: #2789 STIG Sensor reporting out of range (over 55 C) Added: None Resolved: #2734 SKIA Replaced suspicious sensor TS30 Current: #2391 HOLL Reported 15 C warm bias for one month, now data seems to be ok #3147 TIPT Sensor stuck at -273.1 C Added: None Resolved: #2674 BURB Replaced lightning damaged sensor #3391 PAUL Re-positioned sensor found to be installed at 15 cm ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #2539 A149 Replaced sensor with low TDEW bias #3025 A152 Replaced faulty sensor #3026 A182 Replaced faulty sensor SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: #3835 A134 Replaced sensor with warm bias TS15 Current: None Added: None Resolved: #3024 A163 Replaced sensor with sporadic warm bias TS30 Current: None Added: None Resolved: #3018 A146 Replaced erratic sensor #3685 A167 Replaced sensor damaged by rodents ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Suggestions: | |
Measurements: | sgp05okmX1.b1: more
sgp05okmX1.a1: more sgp05okmX1.00: more sgp15okmX1.b1: more sgp15okmX1.a1: more sgp15okmX1.00: more |