Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/01/1999 | 0000 | 11/30/1999 | 2359 | Does not affect quality |
Subject: | SGP/OKM Overview of Automated QA - November 1999 |
DataStreams: | sgp05okmX1.00, sgp05okmX1.b1, sgp15okmX1.b1, sgp15okmX1.a1, sgp05okmX1.a1, sgp15okmX1.00 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the November 1999 Oklahoma Mesonet data. There are a few special events in the November Mesonet data Date Station Parameter(s) ---- ------- ------------ 11/04 CHEY RELH, TAIR Station poked above cold inversion layer; you can disregard the flags WIST TAIR, TA9M Station experienced cold-air drainage; ignore the flags 11/07 BUFF TAIR Cold air drainage; disregard the flags 11/12 WEBB WDIR Localized east-wind anomally; ignore the flags 11/13 BUFF TAIR Cold air drainage; disregard the flags FAIR TAIR Poked above cold inversion; ignore the flags 11/16 CHEY TAIR Poked above cold inversion; ignore the flags 11/27 WIST TAIR Cold air drainage; disregard the flags OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of November, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================= Notes: The influence of the western Oklahoma winter wheat crops was reflected strongly in November's monthly-averaged temperature fields. Temperatures in the wheat-field counties were a solid 1-2 C cooler on average than adjacent counties. The anomaly was also present in the 9-m temperature field, thanks to the increased coverage of stations with 9-m sensors from OASIS. ======================================================================= TAIR Current: #4376 GOOD Sensor stuck at -53.4 C Added: None Resolved: None RELH Current: #4375 GOOD Sensor stuck at 0% Added: None Resolved: None WDIR Current: #4338 MARS Sensor reporting 180 degrees out of phase on numerous occassions #4378 MTHE Sensor stuck at 0 degrees Added: None Resolved: #4233 BBOW Replaced sensor due to suspect windspeed WSPD Current: #4377 MTHE Sensor stuck at 0 m/s Added: None Resolved: #2736 BBOW Replaced sensor due to suspect windspeed PRES Current: #4118 CHEY No barometer hole drilled, sensor is detecting pressure inside enclosure Added: None Resolved: None SRAD Current: #3361 ALTU Monthly QA indicates sensor is reporting ~50 W/m^2 low Added: None Resolved: #4053 LANE Replaced sensor with low bias RAIN Current: #4339 TAHL Gauge stuck at 0.0 mm #4361 HOLL Gauge tipped 66 times instead of 50 times during drip test Added: None Resolved: #3840 COPA Replaced bad switch #3841 NINN Repaired dirt-clogged gauge #4056 VANO Replaced bad switch TA9M Current: None Added: None Resolved: None WS2M Current: #3670 MEDI Sensor at improper height #4296 PORT Sensor stuck at 0.0 m/s #4342 PRES Sensor stuck at 0.0 m/s Added: None Resolved: None TS10 Current: #3003 HOBA Sensor biased 20 C warm Added: #4486 WOOD Sensor appears to be cross-wired #4490 SLAP Sensor appears to be cross-wired Resolved: #3001 ADAX Replaced sensor damaged by gopher #3019 FTCB Re-wired sensor with sporadic reports below -100.0 C #4234 BRIS Replaced lightning-damaged sensor TB10 Current: None Added: #4487 WOOD Sensor appears to be cross-wired Resolved: #3963 FTCB Re-wired sensor stuck below -100.0 C. #4235 BRIS Replaced lightning-damaged sensor TS05 Current: #2604 HOBA Sensor stuck at -273.1 C Added: #4488 WOOD Sensor appears to be cross-wired Resolved: #4236 BRIS Replaced lightning-damaged sensor TB05 Current: None Added: #4489 WOOD Sensor appears to be cross-wired Resolved: #2789 STIG Corrected erosion problem at site #3967 NINN Removed over-grown grass on bare plot TS30 Current: #2391 HOLL Reported 15 C warm bias for one month, now data seems to be ok #3147 TIPT Sensor stuck at -273.1 C Added: #4491 SLAP Sensor appears to be cross-wired Resolved: None ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: #3836 A130 Mesocomp found sensor 7% low #3837 A151 Mesocomp found sensor 7% low Added: None Resolved: None RAIN Current: None Added: None Resolved: #3842 A164 Replaced bad switch TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod |
Suggestions: | |
Measurements: | sgp05okmX1.b1: more
sgp05okmX1.a1: more sgp05okmX1.00: more sgp15okmX1.b1: more sgp15okmX1.a1: more sgp15okmX1.00: more |