Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/25/1996 | 0000 | 03/02/1999 | 2359 | Suspect |
Subject: | TWP/SMET/C1 - Wind speed calibration errors |
DataStreams: | twpsmet60sC1.a1, twpsmet60sC1.b1 |
Description: | Wind speed calibration factors were reversed between wind speed sensors 1 (upper) and 2 (lower). Results in less than 1% error, but correction factors may be used. To correct wind speed #1 (upper) add 0.03 m/s. To correct wind speed #2 (lower) subtract 0.03 m/s. |
Suggestions: | |
Measurements: | twpsmet60sC1.b1: more
twpsmet60sC1.a1: more |