Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
09/01/1999 | 0000 | 09/30/1999 | 2359 | Does not affect quality |
Subject: | SGP/OKM/X1 - Overview of Automated Data Quality - September 1999 |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgp05okmX1.a1, sgp15okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the September 1999 Oklahoma Mesonet data. ============================================================== There are a few special events in the September data that you may want to be aware of. These include: Date Station Parameter(s) ---- ------- ------------ 09/03 ARNE TAIR Thunderstorm; disregard flags 09/07 BREC TB10, TB05 Rainfall dramatically cooled hot soils; ignore the flags 09/07 NEWK TAIR Thunderstorm; disregard flags 09/07 SALL TAIR Thunderstorm; disregard flags 09/08 BREC TB05 Rainfall dramatically cooled hot soil; ignore the flags 09/08 JAYX PRES Meso-high occured from thunderstorms; ignore the flags 09/08 MARS TB05 Rainfall cooled soil; ignore the flags 09/10 BUFF RELH, TAIR Thunderstorm; disregard flags -Chris ======================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of September, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================= Notes: The Mesonet technicians were busy in September resolving over 37 trouble tickets. Lightning at OKEM and BRIS, along with the hot summer of 1999 really made the problems pile up. In addition to this, 9 sites were upgraded for the OASIS project, and one site (BOIS) was upgraded to a Super Site. ======================================================================== TAIR Current: None Added: None Resolved: None RELH Current: #3004 BREC Sensor dropping to near 0% RELH on several occasions #3012 CHER Sensor stuck at 0% RELH Added: None Resolved: #3000 NEWK Replaced sensor stuck at 0% RELH #3016 OKEM Replaced lightning-damaged sensor #3030 BRIS Replaced lightning-damaged sensor WDIR Current: #2711 HOOK Sensor reporting E-NE'ly during southerly flow Added: None Resolved: #3076 OKEM Replaced lightning-damaged sensor WSPD Current: #2736 BBOW Sensor suspected of under-reporting during strong winds/severe weather Added: None Resolved: #3075 OKEM Replaced lightning-damaged sensor #3010 TISH Replaced bad bearings #3011 KING Replaced sensor stuck at 0 m/s #3014 ARDM Replaced noisy bearings PRES Current: None Added: None Resolved: #3150 OILT Repaired sensor stuck at 978.49 mb SRAD Current: None Added: #3361 ALTU Monthly QA indicates sensor is reporting ~50 W/m^2 low Resolved: None RAIN Current: #2681 BURB Switch found to be sticking Added: None Resolved: #2640 ANTL Replaced double-tipping gauge #2797 CHER Replaced faulty switch #2998 WEBB Replaced faulty switch #2999 VINI Replaced faulty switch TA9M Current: None Added: #3360 BREC Roughly half of observations each day are below 0. Resolved: None WS2M Current: None Added: None Resolved: #2946 STIG Replaced sensor stuck at 0.0 m/s #2997 PAUL Replaced noisy bearings #3017 WEBB Removed tall johnson grass that was impeding cup rotation TS10 Current: #2260 BOWL Sensor reporting data spikes and 5 C warm bias #2673 BURB Sensor appears to be biased 5 C warm since lightning strike #3001 ADAX Stuck at less than -100.0 C #3003 HOBA Sensor biased 20 C warm #3019 FTCB Sensor reporting numerous observations below -100.0 C Added: None Resolved: #2831 IDAB Corrected wiring problem #2839 PAWN Corrected wiring problem #2840 TIPT Corrected wiring problem #3077 OKEM Replaced lightning-damaged sensor TB10 Current: #2864 FREE Sensor stuck at -73 C Added: None Resolved: #2799 MIAM Replaced faulty sensor #2833 IDAB Corrected wiring problem #2837 PAWN Corrected wiring problem TS05 Current: #2604 HOBA Sensor stuck at -273.1 C Added: #3359 WYNO Monthly QA indicates 5 C warm bias Resolved: #2832 IDAB Corrected wiring problem #2838 PAWN Corrected wiring problem #2841 TIPT Corrected wiring problem #2993 PRYO Repaired faulty sensor TB05 Current: #2538 CATO Sensor biased 5-10 C warm #2734 SKIA Reporting data spikes in the afternoon and as much as a 10 C warm bias #2789 STIG Sensor reporting out of range (over 55 C) Added: None Resolved: #2719 LAHO Replaced warm-biased sensor #2834 IDAB Corrected wiring problem #2994 PRYO Replaced faulty sensor TS30 Current: #2391 HOLL Reported 15 C warm bias for one month, now data seems to be ok #2674 BURB Sensor biased 12 C cool since lightning strike Added: None Resolved: #2274 SALL Replaced lightning-damaged sensor #2836 PAWN Corrected wiring problem #3078 OKEM Replaced lightning-damaged sensor #3147 TIPT Sensor stuck at -273.1 C ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: #2539 A149 Monthly QA indicates 1.0 C low TDEW bias #3025 A152 Sensor observing many -7999.0 obs #3026 A182 Sensor observing many -7999.0 obs Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: #3024 A163 Sensor biased 8 C warm Added: None Resolved: None TS30 Current: #3018 Sensor failing step test with frequent erratic observations and 5 C warm bias Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Suggestions: | |
Measurements: | sgp05okmX1.b1: more
sgp05okmX1.a1: more sgp15okmX1.b1: more sgp15okmX1.a1: more |