DQRID : D990224.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
02/08/1999190002/09/19991530Incorrect
02/10/1999193002/11/19992300Incorrect
more
Subject:
SGP/SMOS/E9 - Incorrect E9 RH data
DataStreams:sgp1smosE9.00, sgp1440smosE9.a0, sgp30smosE9.a1, sgp1smosE9.a0
Description:
For unknown reason or reasons the E9 SMOS reported incorrect RH data starting
on 8 FEB 99 at 1900 until 9 FEB 99 at 1530.  All humidity data reported during
that period should be flagged as incorrect.

Field techs found nothing wrong with the probe or the data when they checked
it on their rounds 18 FEB 99.
Suggestions: 
None, other than flagging the data, at this time.
Measurements:sgp1smosE9.a0:
  • vap_pres
  • rh
more
sgp1440smosE9.a0:
  • time_max_vap_pres
  • min_vap_pres
  • time_min_vap_pres
  • max_vap_pres
  • time_max_rh
  • time_min_rh
  • max_rh
  • min_rh
more
sgp30smosE9.a1:
  • sd_rh
  • sd_vap_pres
  • rh
  • vap_pres
more
sgp1smosE9.00:
  • Raw data stream - documentation not supported
more