Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
03/01/1999 | 0000 | 03/31/1999 | 2359 | Does not affect quality |
Subject: | SGP/OKM - Overview of Automated QA - March 1999 |
DataStreams: | sgp05okmX1.00, sgp15okmX1.00, sgp15okmX1.a1, sgp05okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the March 1999 Oklahoma Mesonet data. There are a few special events that were flagged by the automatic qa that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 03/01 MEDI TAIR - Station poked above the cold inversion layer; disregard the flags. 03/15-16 MEDF TAIR - Isolated deep snow cover caused this station's temperatures to be much colder than neighbors; ignore flags -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of March, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================== Notes: Vandalization: The A149 Micronet station suffered extensive damage shortly after midnight on March 17. All sensors were damaged except TS05, TS10, and TS30. ======================================================================== TAIR Current: None Added: None Resolved: None RELH Current: #2151 RING Sensor sporadically reporting ~30% too low Added: None Resolved: #2228 STIG Replaced sensor reporting near 0% RH WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #2242 BESS Replaced sensor with broken shaft PRES Current: None Added: None Resolved: #2240 STIG Lose wire found to be cause of stuck pressure readings SRAD Current: #2212 SPEN Sensor consistently reports lower than neighboring sites Added: None Resolved: #2239 MEDI Replaced sensor stuck at 0 W/m RAIN Current: None Added: None Resolved: #2238 ALV2 Reed switch broken; causing momentary contacting of switch elements TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #2188 HINT Long-term QA indicates 1-2 C cool bias #2234 MINC Monthly QA indicates 3 C warm bias #2236 VINI Warm bias, data spikes, and multiple observations of -273.1 C noted Added: #2260 BOWL Sensor reporting data spikes and 10 C warm bias Resolved: None TB10 Current: #2213 GUTH Long-term QA indicates 2-3 C warm bias Added: None Resolved: None TS05 Current: #2187 HINT Long-term QA indicates 1-2 C cool bias Added: None Resolved: None TB05 Current: #2015 ELRE Sensor reporting 2 C warmer than neighboring sites Added: None Resolved: None TS30 Current: #2184 FTCB Long-term QA indicates 1-2 C cool bias Added: None Resolved: None ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: #2179 A155 Replaced sensor which reported as high as 105 0uring high humidity #2248 A149 Replaced sensor damaged by vandalism SRAD Current: None Added: None Resolved: #2249 A149 Replaced sensor damaged by vandalism RAIN Current: None Added: None Resolved: #2251 A149 Replaced funnel broken by vandalism TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: #2250 A149 Insulation cut when site vandalized TS30 Current: None Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== |
Suggestions: | Users of these data should obtain the detailed quality assurance information from ARM |
Measurements: | sgp05okmX1.a1: more
sgp05okmX1.00: more sgp15okmX1.a1: more sgp15okmX1.00: more |