Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/01/1999 | 0000 | 04/30/1999 | 2359 | Does not affect quality |
Subject: | SGP/OKM - Overview of Automated QA - April 1999 |
DataStreams: | sgp05okmX1.00, sgp15okmX1.00, sgp15okmX1.a1, sgp05okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the April 1999 Oklahoma Mesonet data. There is one special event that was flagged by the automatic qa that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 04/04 BYAR,MEDI TAIR,RELH - Stations poked above the cold inversion layer; disregard the flags. -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of April, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================== Forces of Nature: SHAW, SALL and CLAY were each struck by lightning during the month of April, causing varying degrees of damage to the instrumentation at those sites. CLAY is no stranger to lightning strikes. This was its third strike since its birth in March of 1994. As a preview to next month's QA report, I'd like to note that CLAY saw its FOURTH strike just last week! Bulls were reported to have attacked BRIS during April, knocking down a pyranometer stand, destroying the temperature and RH sensor, and causing damage to the rain gauge there. Mischievous cows also knocked down the pyranometer stand at WASH. On to the report... ======================================================================== TAIR Current: None Added: None Resolved: #2263 BRIS Sensor destroyed by bull #2275 SALL Sensor destroyed by lightning #2383 CLAY Sensor damaged by lightning RELH Current: #2151 RING Sensor sporadically reporting data spikes #2295 PAWN Sensor damaged by storm #2297 CHIC Sensor sticking at 0% RELH Added: #2327 COPA Sensor reached a max RH of only 94.7% during the month of April #2377 MAYR Monthly QA indicates 1.5 C low TDEW bias #2376 KING Monthly QA indicates 2 C high TDEW bias Resolved: #2262 BRIS Sensor destroyed by bull #2270 SALL Sensor destroyed by lightning #2382 CLAY Sensor damaged by lightning WDIR Current: #2276 BBOW Sensor possibly sticking during low winds Added: None Resolved: #2277 SHAW Lightning strike damaged wind tranzorbs #2384 CLAY Possible lightning damage; lab tested WSPD Current: None Added: None Resolved: #2385 CLAY Possible lightning damage; lab tested PRES Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: #2212 SPEN Sensor found to have greater than 5% error #2264 BRIS Stand knocked over by bull #2266 WASH Stand knocked down by cows #2268 SALL Sensor destroyed by lightning strike #2386 CLAY Sensor damaged by lightning RAIN Current: None Added: None Resolved: #2267 BRIS Gauge repaired after bull attack TA9M Current: #2326 CLAY Sensor stuck at -459 C Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #2188 HINT Long-term QA indicates 1-2 C cool bias #2234 MINC Monthly QA indicates 5 C warm bias #2260 BOWL Sensor reporting data spikes and 5 C warm bias Added: None Resolved: #2236 VINI Replaced sensor reporting data spikes #2387 CLAY Sensor damaged by lightning TB10 Current: #2213 GUTH Long-term QA indicates 10 C warm bias #2325 MARE Sensor reporting 5 C warm bias Added: #2329 IDAB Monthly QA indicates 5 C warm bias Resolved: #2324 WYNO Replaced sensor with intermittent data spikes TS05 Current: #2187 HINT Long-term QA indicates 1-2 C cool bias Added: None Resolved: #2388 CLAY Sensor damaged by lightning TB05 Current: None Added: #2328 HOBA Monthly QA indicates 4 C cool bias at night, 4 C warm bias during day Resolved: #2015 ELRE Replaced sensor with warm bias #2259 NORM Repaired sensor with lose wire #2389 CLAY Sensor damaged by lightning TS30 Current: #2184 FTCB Long-term QA indicates 1-2 C warm bias #2274 SALL Sensor damaged by lightning Added: None Resolved: #2390 CLAY Sensor damaged by lightning ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: #2296 A148 Gauge stopped reporting during heavy rain event Added: None Resolved: None TS05 Current: None Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== Chris Fiebrich May 10, 1999 |
Suggestions: | Users of these data should obtain the detailed quality assurance information from ARM |
Measurements: | sgp05okmX1.a1: more
sgp05okmX1.00: more sgp15okmX1.a1: more sgp15okmX1.00: more |