DQRID : D990623.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/13/1999123006/11/19991645Incorrect
more
Subject:
SGP/EBBR/E9 - Right Aspirator Not Working
DataStreams:sgp5ebbrE9.b1, sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
The result of the right aspirator not working was a reduction in measured
temperature gradient and thus a reduction in estimated sensible heat flux
and an increase in latent heat flux.  The fluxes could be in error by as
much as 10%.  Reported right air and humidity probe temperatures, top and 
bottom air and humidity probe temperatures, right relative humidity, and 
top and bottom vapor pressure are affected.
Suggestions: 
Measurements:sgp30ebbrE9.b1:
  • vapor_pressure_top
  • temp_air_bottom
  • temp_trh_top
  • latent_heat_flux
  • temp_air_top
  • rh_top_fraction
  • rh_bottom_fraction
  • sensible_heat_flux
  • vapor_pressure_bottom
  • temp_trh_bottom
more
sgp15ebbrE9.b1:
  • temp_air_right
  • temp_air_left
  • rh_right_mv
  • rh_left_mv
  • temp_trh_right_rr
  • temp_trh_left_rr
more
sgp5ebbrE9.b1:
  • vapor_pressure_top
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_top
  • temp_air_bottom
  • rh_top_fraction
  • vapor_pressure_bottom
  • temp_trh_bottom
more

Close this window