Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
05/01/1999 | 0000 | 05/30/1999 | 2359 | Does not affect quality |
Subject: | Overview of Automated QA - May 1999 |
DataStreams: | sgp05okmX1.00, sgp15okmX1.00, sgp15okmX1.a1, sgp05okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the May 1999 Oklahoma Mesonet data. There are a few special events that were flagged by the automatic qa that you may want to be aware of: Date Station Parameter(s) ---- ------- ------------ 5/9 ERIC WSPD Localized thunderstorms produced strong winds at ERIC; disregard the flags 5/10 HOLL PRES Intense thunderstorm and meso- high moved near the HOLL site; disregard the flags 5/17 CHEY WSPD, WS2M Thunderstorm caused localized wind gusts of 70 mph at this site; you can ignore the flags ERIC PRES | Strong thunderstorms and meso-highs PUTN PRES |------- moved over these sites causing their TIPT PRES | pressure observations to be spatially off; disregard the flags 5/20 CAMA PRES Localized intense thunderstorm and high wind gusts caused this site's pressure observations to be spatially inconsistent with neighbors; ignore the flags 5/23 HASK WSPD Strong wind speeds to over 65 mph associated with thunderstorms caused this data to be flagged; disregard the flags 5/26 TIPT WSPD Meso-low forming in advance of a strong thunderstorm caused the strong winds at TIPT; ignore the flags -Chris Fiebrich Mesonet QA Manager ========================================================================= OKLAHOMA MESONETWORK/ARS QUALITY ASSURANCE REPORT for the month of May, 1999 Based upon observations taken at 1800 UTC each day Prepared by Chris Fiebrich (qamgr@redrock.ocs.ou.edu) ======================================================================== TAIR Current: None Added: None Resolved: None RELH Current: #2151 RING Sensor sporadically reporting data spikes #2295 PAWN Sensor damaged by storm #2376 KING 2 C warm TDEW bias suspected #2377 MAYR 1.5 C low TDEW bias suspected #2394 BRIS Data sporadically drops to less than 10% RH #2486 ALV2 Sensor reporting constant 0% RH Added: None Resolved: #2297 CHIC Replaced sensor stuck at 0% RH WDIR Current: #2276 BBOW Sensor possibly sticking during low winds #2393 CHER Sensor reporting easterly winds during periods of strong westerlies Added: None Resolved: None WSPD Current: None Added: None Resolved: #2407 NORM Tightened wires at site to remedy false wind observations of 0 m/s #2408 NOWA Replaced nose cone to fix sticking PRES Current: #2441 GUTH Sensor reported 40 mb drop in 12 h #2442 WEAT Sensor reported 80 mb drop in 12 h #2487 OILT Sensor reporting long-duration data dips of as much as 80 mb daily Added: None Resolved: None SRAD Current: #2440 WALT Sensor reporting numerous data spikes daily #2501 CHIC Sensor reporting recurrent data dips to 0 W/m during daytime hours Added: None Resolved: None RAIN Current: #2405 ANTL Gauge suspected to be double-tipping Added: None Resolved: None TA9M Current: #2326 CLAY Sensor stuck at -459 C Added: None Resolved: None WS2M Current: None Added: None Resolved: None TS10 Current: #2188 HINT Long-term QA indicates 1-2 C cool bias #2234 MINC Monthly QA indicates 5-10 C warm bias #2260 BOWL Sensor reporting data spikes and 5 C warm bias Added: None Resolved: #2434 SEIL Repaired wiring problem TB10 Current: #2213 GUTH Long-term QA indicates 10 C warm bias Added: None Resolved: #2433 SEIL Repaired wiring problem #2329 IDAB Replaced sensor with warm bias #2325 MARE Sensor tested fine during site visit TS05 Current: #2187 HINT Long-term QA indicates 1-2 C cool bias Added: None Resolved: #2432 SEIL Repaired wiring problem TB05 Current: None Added: None Resolved: #2435 SEIL Repaired wiring problem #2328 HOBA Rock in soil causing erroneous sensor depth; removed rock and re-installed sensor TS30 Current: #2184 FTCB Long-term QA indicates 1-2 C warm bias #2274 SALL Sensor damaged by lightning #2391 HOLL Reporting 15 C warm bias Added: None Resolved: None ------------------------------------------------------------------------- ARS QA REPORT ------------------------------------------------------------------------- TAIR Current: None Added: None Resolved: None RELH Current: None Added: #2539 A149 Monthly QA indicates 1.0 C low TDEW bias Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: #2296 A148 Replaced bad switch TS05 Current: #2438 A155 Sensor biased 10 C warm Added: None Resolved: None TS10 Current: None Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: None Added: None Resolved: None ========================================================================= LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod =========================================================================== Chris Fiebrich June 10, 1999 |
Suggestions: | Users of these data should obtain the detailed quality assurance information from ARM |
Measurements: | sgp05okmX1.a1: more
sgp05okmX1.00: more sgp15okmX1.a1: more sgp15okmX1.00: more |