DQRID : D991019.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
10/13/1999142010/14/19992230Incorrect
more
Subject:
SGP/THWAPS - THWAPS pressure too high by factor of 1.1
DataStreams:DsgpthwapsC1.b1, DsgpthwapsC1.00, DsgpthwapsC1.a1
Description:
When attempting to reprogram the C1 THWAPS Campbell Scientific data logger
to correct the problem (previously reported) with RH, Site Ops mistakenly
changed the scaling of the pressure sensor instead.  Pressure data in
the ingested file is 1.1 too high.  The RH is 1.1 too low (subject of
a different DQR).
Suggestions: 
Measurements:DsgpthwapsC1.b1:
  • Development data stream - documentation not supported
more
DsgpthwapsC1.00:
  • Development raw data stream - documentation not supported
more
DsgpthwapsC1.a1:
  • Development data stream - documentation not supported
more

Close this window