Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/25/1999 | 0450 | 04/02/2000 | 0000 | Does not affect quality |
Subject: | TWP/SMET/C1 - Wind Direction alignment method |
DataStreams: | twpsmet60sC1.a1, twpsmet60sC1.b1, twpsmet60sC1.00 |
Description: | During RESET10 we discovered a problem with wind direction from WIND1 (upper anemometer). During RESET8, WIND1 was corrected by rotating the alignment ring instead of the anemometer. This resulted in a better agreement between the 2 anemometers, but is not the correct way to align an anemometer. The alignment ring was readjusted for true north and the anemometer reset in the proper slot (the original problem). |
Suggestions: | Data should be unaffected. |
Measurements: | twpsmet60sC1.b1: more
twpsmet60sC1.a1: more twpsmet60sC1.00: more |