SGP/EBBR/E8 - E8 EBBR AEM Stuck In One Position
DataStreams:sgp30ebbrE8.b1, sgp15ebbrE8.b1, sgp5ebbrE8.b1
Description:
The raw temperature and humidity data is incorrect and thus Bowen ratio, 
and half hour sensible and latent heat flux are incorrect for much of this period.  Please 
look at the home signal qc to determine whether the data is indeed incorrect.

Normally I do not submit DQRs for this condition, but the frequency of
the problem was high for this site.
Suggestions: 
Measurements:sgp5ebbrE8.b1:
  • temp_trh_top
  • temp_air_bottom
  • rh_bottom_fraction
  • temp_trh_bottom
  • vapor_pressure_bottom
  • rh_top_fraction
  • vapor_pressure_top
  • temp_air_top
more
sgp15ebbrE8.b1:
  • temp_air_right
  • temp_air_left
  • temp_trh_left_rr
  • rh_right_mv
  • rh_left_mv
  • temp_trh_right_rr
more
sgp30ebbrE8.b1:
  • vapor_pressure_bottom
  • latent_heat_flux
  • temp_air_bottom
  • temp_trh_bottom
  • rh_bottom_fraction
  • sensible_heat_flux
  • rh_top_fraction
  • vapor_pressure_top
  • bowen_ratio
  • temp_trh_top
  • temp_air_top
more