SGP/SMOS/E21 - E21 MAX WIND SPEED IN ERROR
DataStreams:sgp1440smosE21.a1
Description:
Max wind speed in error sue to an incorrect multiplier in the datalogger program 
converting RPM to m/s.  The multiplier was corrected and wind speed values correct after 16:31z.  
Incorrect multiplier is .09720, correct multiplier .00496.
Suggestions: 
To calculate the correct wind speed, subtract .10 from incorrect value, divide result 

by .09720, multiply result by .00496, add .10.