DQRID : D020717.27
Start DateStart TimeEnd DateEnd Time Data Quality Metric
11/01/2001000006/30/20022356Incorrect
more
Subject:
SGP/EBBR/E19 - Reprocess: Soil Temperature #3 Incorrect
DataStreams:sgp30ebbrE19.b1
Description:
Soil Temperature 3 was incorrect for the period indicated, causing average soil flow, 
latent heat flux, and sensible heat flux to be incorrect also.

Average soil heat flow, sensible heat flux, and latent heat flux can be recalculated using 
the remaining good sets of soil sensors as follows:

ave_shf = (g1 + g2 + g4 + g5)/4

e = -(q + ave_shf)/(1 + bowen)

h = -(q + e + ave_shf)
Suggestions: 
Measurements:sgp30ebbrE19.b1:
  • surface_soil_heat_flux_avg
  • energy_storage_change_3
  • soil_temp_3
  • sensible_heat_flux
  • latent_heat_flux
  • surface_soil_heat_flux_3
more