DQRID : D050117.10
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/30/1997100006/30/20032359Incorrect
more
Subject:
SGP/EBBR/E19 - BA EBBR VAP Bulk Aerodynamics
DataStreams:sgp30baebbrE19.c1
Description:
Fixed AEM and wind speed sensor heights were improperly used in the
calculation of bulk aerodynamic sensible and latent heat fluxes instead of
site specific heights.
      
This resulted in either under-estimation or over-estimation of the sensible
and latent heat fluxes.
Suggestions: 
Measurements:sgp30baebbrE19.c1:
  • ecomb
  • austar
  • ale
  • hcomb
  • ah
more