Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
10/13/2003 | 0000 | 09/29/2004 | 1845 | Incorrect |
Subject: | SGP/EBBR/E26 - Spark Gap Bad, Pressure Incorrect |
DataStreams: | sgp5ebbrE26.b1, sgp15ebbrE26.b1, sgp30ebbrE26.b1 |
Description: | In a trip to E26, I found that a bad spark gap through which the barometer was powered was causing pressure measurements to be incorrect. The pressure readings oscillated with the voltage of the EBBR battery. During daytime the voltage and thus the pressure would increase and vice versa during dark hours. Apparently only the positive side of the power supply was properly connected through the spark gap and thus the voltage received by the pressure sensor was lower than required to power it properly. Under this condition the perssure measurement varies with voltage level. The pressure measurements therefore had a diurnal signature and usually were incorrect. The decreased pressure during most times would cause latent heat flux to be slightly overestimated and sensible heat flux to be slightly underestimated. |
Suggestions: | |
Measurements: | sgp5ebbrE26.b1: more
sgp15ebbrE26.b1: more sgp30ebbrE26.b1: more |