Description: | See below for details of reprocessing that was completed on 20150929. Original
DQR category: 4 (Red, Incorrect).
-----------------------------------------------------------
During the pyrgeometer instrument (PIR) changout a datalogger program was loaded with
incorrect calibration coefficients for the shortwave instruments. The affected measurements
were : downwelling diffuse (DD), upwelling shortwave(US), direct normal (NIP) and
downwelling shortwave(DS)
Recalculate irradiances by determining original mV signal and reapplying the correct
calibration coefficients. For each one minute irradiance value perform the following
calculations by instrument:
DD(corrected) = (DD/107.24)*118.11
US(corrected) = (US/113.19)*118.21
NIP(corrected)= (NIP/120.17)*119.08
DS(corrected) = (DS/118.46)*117.33 |