DQRID : D050104.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/20/2004000009/02/20040400Does not affect quality
more
Subject:
TWP/SKYRAD/C3 - Reprocessed and Corrected: NIP calibrations incorrect
DataStreams:twpskyradC3.00, twpskyrad60sC3.b1
Description:
DATA REPROCESSED and CORRECTED: 

During installation of the new Campbell datalogger system and associated program, the NIP 
(S/N 33551E6) was assigned an incorrect calibration coefficient. A coefficient of 116.01 
W/m2/mV was applied when it should have been 124.378 W/m2/mV. The correct calibration 
coefficient has now been applied.

The data were archived April 2017. Please retrieve the reprocessed data for use in your 
analysis.

You may find these data using the ARM Discovery tool at the following link:
http://www.archive.arm.gov/discovery/#v/results/s/finst::skyrad/fsite::twp/ffac::twp.C3 


ORIGINAL DQR CATEGORY: Red( Incorrect)

REPROCESSED and CORRECTED DATA ARCHIVED:2017-04

REPROCESS IDENTIFICATION NUMBER: RID 184

---------------------------------------------------
--- ORIGINAL DQR DESCRIPTION ---
---------------------------------------------------


On 05/20 during installtion of the new Campbell datalogger system and associated program 
the NIP (S/N 33551E6) was assigned an incorrect calibration coefficient.  A coefficient of 
116.01 W/m2/mV was applied when it should have been 124.378 W/m2/mV.
TWP reports SV0405D and SV0409D detail the activities which lead to this DQR.
Suggestions: 
Measurements:twpskyradC3.00:
  • Raw data stream - documentation not supported
more
twpskyrad60sC3.b1:
  • short_direct_normal_std
  • short_direct_normal_min
  • short_direct_normal
  • short_direct_normal_max
more