DQRID : D050222.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/14/2004000006/14/20040030Does not affect quality
more
Subject:
SGP/ECOR/E6  - Reprocess: Incorrectly flagged (marked as "bad") H2O/CO2 data
DataStreams:sgp30ecorE6.b1
Description:
Due to system clock instability on ECOR computers their system time is adjusted 
approximately once per hour; sometimes this adjustment leads to backward time jumps over midnight, 
into the previous day. In this case all the data based on CO2/H2O measurements might be 
erroneously marked as bad. Below is a list of times when that might have happen.

SITE    YEAR    MONTH   DAY     HOUR    MINUTE
06      2004    06      14      00      00
Suggestions: 
Correct data may be restored by reprocessing raw data (sonic and IRGA, 00 level) with 

current ECOR processing program (version 1.9 or later).
Measurements:sgp30ecorE6.b1:
  • cvar_rot_wc
  • mean_c
  • cvar_rot_uc
  • skew_q
  • cvar_qc
  • mean_spk_c
  • n_good_q
  • cvar_uq
  • cvar_wq
  • cvar_rot_uq
  • var_q
  • cvar_rot_wq
  • cvar_vc
  • mean_spk_q
  • kurt_q
  • real_cp
  • mr
  • lv_e
  • var_c
  • n_spk_c
  • lv
  • real_mr
  • cvar_rot_vc
  • cvar_tc
  • cvar_tq
  • cvar_vq
  • kurt_c
  • n_spk_q
  • n_bad_q
  • cvar_rot_vq
  • mean_q
  • fc
  • rho
  • cvar_uc
  • cvar_wc
  • n_bad_c
  • n_good_c
  • skew_c
  • real_rho
  • real_lv
more

Close this window