DQRID : D120522.8
Start DateStart TimeEnd DateEnd Time Data Quality Metric
10/13/2004051310/31/20042230Incorrect
more
Subject:
TWP/QCRAD/C1 - Reprocess: NIP calibration
DataStreams:twpqcrad1longC1.s1, twpqcrad1longC1.c1, twpqcrad1longC1.s2, twpqcrad1longC1.c2
Description:
Direct normal flux has incorrect calibration coefficient but can be fixed as described in 
instrument DQR D041106.1:

The tracker rotated and pulled the cable away from the NIP connector. In trying to 
discover
the problem with the NIP a new NIP was put in. When the problem turned out to be the 
cable,
the observers didn't put the former NIP back in. The NIP then in service was 31346E6
RS@45=8.1573 whereas the coefficients used were for the old NIP 299937E6 RS@45=7.8775
Suggestions: 
Correct direct normal flux as described. Recalculate best estimate flux or use 

downwelling shortwave if "source_BestEstimate_down_short_hemisp" is 0 during this period.
Measurements:twpqcrad1longC1.s1:
  • BestEstimate_down_short_hemisp
  • short_direct_normal
more
twpqcrad1longC1.c1:
  • short_direct_normal
  • BestEstimate_down_short_hemisp
more
twpqcrad1longC1.c2:
  • BestEstimate_down_short_hemisp
  • short_direct_normal
more
twpqcrad1longC1.s2:
  • short_direct_normal
  • BestEstimate_down_short_hemisp
more