DQRID : D050324.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
02/05/2004170003/05/20051730Does not affect quality
more
Subject:
SGP/EBBR/E19 -  Reprocessed and Corrected:Negative Net Rad calibrations
DataStreams:sgp30ebbrE19.b1, sgp5ebbrE19.b1
Description:
DATA REPROCESSED and CORRECTED: 

The calibration for negative net radiation was incorrectly entered in the datalogger 
program. The values were reprocessed by multiplying all negative net radiation values by 0.942.

The data were archived February 2017. Please retrieve the reprocessed data for use in your 
analysis.

You may find these data using the ARM Discovery tool at the following link:
http://www.archive.arm.gov/discovery/#v/results/s/finst::ebbr/fsite::sgp/ffac::sgp.E19 

ORIGINAL DQR CATEGORY: Red( Incorrect)

REPROCESSED and CORRECTED DATA ARCHIVED:2017-02

REPROCESS IDENTIFICATION NUMBER: RID 191

---------------------------------------------------
--- ORIGINAL DQR DESCRIPTION ---
---------------------------------------------------

The calibration for negative net radiation was incorrectly entered in the datalogger 
program.
Suggestions: 
Measurements:sgp30ebbrE19.b1:
  • sensible_heat_flux
  • latent_heat_flux
  • net_radiation
more
sgp5ebbrE19.b1:
  • net_radiation
more