Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/28/1996 | 0000 | 11/14/2009 | 1107 | Suspect |
Subject: | SGP/SWATS/E24 - Questionable Data due to placement of instrument |
DataStreams: | sgpswatsE24.a1, sgpswatsE24.b1, sgpswatsE24.01, sgpswatsE24.00 |
Description: | The Cyril EF is located on a gypsum outcropping overlooking a wheat field. When the SWATS was installed, it was placed in a "hole" in the gypsum filled with soil. The IM does not believe that this is conducive to collection of data that would be representative of local soil moisture conditions due to this arrangement. While the soil temperature and moisture data are correct for the conditions in that spot, it is very likely that the gypsum surroundings create an environment that would be unlike the surrounding area, and should be aware that the data may not be representative of actual mean local conditions. |
Suggestions: | Use caution when using this data. |
Measurements: | sgpswatsE24.01: more
sgpswatsE24.a1: more sgpswatsE24.00: more sgpswatsE24.b1: more |