DQRID : D071001.3
Start DateStart TimeEnd DateEnd Time Data Quality Metric
08/28/1996000011/14/20091107Suspect
more
Subject:
SGP/SWATS/E24 - Questionable Data due to placement of instrument
DataStreams:sgpswatsE24.a1, sgpswatsE24.b1, sgpswatsE24.01, sgpswatsE24.00
Description:
The Cyril EF is located on a gypsum outcropping overlooking a wheat field.  When the SWATS 
was installed, it was placed in a "hole" in the gypsum filled with soil.  The IM does 
not believe that this is conducive to collection of data that would be representative of 
local soil moisture conditions due to this arrangement.

While the soil temperature and moisture data are correct for the conditions in that spot, 
it is very likely that the gypsum surroundings create an environment that would be unlike 
the surrounding area, and should be aware that the data may not be representative of 
actual mean local conditions.
Suggestions: 
Use caution when using this data.
Measurements:sgpswatsE24.01:
  • Raw data stream - documentation not supported
more
sgpswatsE24.a1:
  • tsoil_E
  • tsoil_W
  • soilwatpot_E
  • soilwatpot_W
more
sgpswatsE24.00:
  • Raw data stream - documentation not supported
more
sgpswatsE24.b1:
  • soilwatpot_E
  • watcont_E
  • watcont_W
  • tsoil_W
  • tsoil_E
  • soilwatpot_W
more

Close this window