Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
07/01/2009 | 0100 | 10/15/2009 | 0300 | Suspect |
Subject: | TWP/SMET/C2 - Induced wind speed when calm |
DataStreams: | twpsmet60sC2.b1 |
Description: | The upper and lower wind sensors were not trending well at wind speed below 1 m/s. Both sensors were showing values above 0m/s when calm. The lightning protector was at fault resulting in an induced wind voltage during calm conditions. Users should subtract any offset found (for example 0.19 m/s for upper wind speed) when the wind speeds are flat-lined. The offset value was not consistent. |
Suggestions: | |
Measurements: | twpsmet60sC2.b1: more
|