DQRID : D120420.6
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/18/2009175107/31/20091645Incorrect
more
Subject:
SGP/QCRAD/C1 - SW direct normal data drop out
DataStreams:sgpqcrad1longC1.c2, sgpqcrad1longC1.s2, sgpqcrad1longC1.s1, sgpqcrad1longC1.c1
Description:
NIP cable had failed during this time period.  Short_direct_normal data are not 
recoverable during this time period. However, it can be reconstructed using the following formula 
for each one minute data:
   short_direct_normal = (down_short_hemisp-down_short_diffuse_hemisp)/cos(zenith angle)

Documented in instrument DQR D090623.1
Suggestions: 
Use direct normal measurements from E13 or calculate from diffuse and global.