DQRID : D130424.3
Start DateStart TimeEnd DateEnd Time Data Quality Metric
07/14/2012000007/14/20121042Suspect
more
Subject:
PVC/WSACR/M1 - Transmitter Down for Sectors of RHI Scan
DataStreams:pvcwsacrhsrhiC1.a1
Description:
The transmitter was down for sectors of the RHI scans during this period.  The sector 
looks to change with every scan.  There are still usable data in these scans.
Suggestions: 
Remove the bad sectors from analysis
Measurements:pvcwsacrhsrhiC1.a1:
  • snr
  • reflectivity
  • linear_depolarization_ratio
  • spectral_width
  • mean_doppler_velocity
more