DQRID : D130709.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
06/28/2013012507/05/20131540Missing
more
Subject:
SGP/SIRS/C1 - NIP sensor failure
DataStreams:sgpsirsC1.b1, sgpsirs20sC1.a0
Description:
The short_direct_normal data are missing due to an instrument failure (NIP pyhrheliometer) 
likely due to a nearby lightning strike near the time of initial failure.

The short_direct_normal data are not recoverable during this time period.  However, direct 
normal data can be reconstructed from the down_short_diffuse_hemisp and 
down_short_hemisp using the following relationship for each data point:
short_direct_normal = (down_short_hemisp - down_short_diffuse_hemisp)/cos(zenith angle)
Suggestions: 
Measurements:sgpsirsC1.b1:
  • short_direct_normal_std
  • short_direct_normal_max
  • short_direct_normal_min
  • short_direct_normal
more
sgpsirs20sC1.a0:
  • inst_direct_normal
more