DQRID : D130924.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
12/05/2010000001/02/20150000Does not affect quality
more
Subject:
TWP/RLPROF/C3 - Metadata/Data Type Inconsistencies
DataStreams:twp10rlprofbe1newsC3.c1, twp10rlprofbe1newsC3.s1
Description:
The cmask, temperature, and pressure fields are using improper metadata for the long_name 
variable attribute. In each of these fields, the long_name changes depending on the 
source used for each field. This creates a conflict with the DOD version listed in the global 
attributes for these datastreams, as the long_name should be static for a specific DOD 
version. This VAP is listing a single DOD version despite these differences.  This creates 
a problem with the metadata stored in the Archive databases, which also expect the 
long_name for a field to be constant over time.  

As a result, the long_name listed for the temperature field in the "Extract Specific 
Measurements" option of the Archive Data Discovery ordering interface is "Temperature from 
sgpaeriprof3feltzC1.c1".  This is the case even if you are ordering data for the 
twp10rlprofbe1newsC3.c1 and twp10rlprofbe1newsC3.s1 datastreams. This is obviously incorrect, and 
the user will have to check the data files to see that the long_name of the temperature 
field is actually "Temperature from twpsondewnpnC3.b1".  

Likewise, the long_name listed for the pressure field in the "Extract Specific 
Measurements" option of the Archive Data Discovery ordering interface is "Pressure from 
sgpaeriprof3feltzC1.c1".  This is incorrect, and long_name in the data files is "Pressure from 
twpsondewnpnC3.b1".  

Finally, the long_name listed for the cmask field in the "Extract Specific Measurements" 
option of the Archive Data Discovery ordering interface is always "Cloud mask from 
depolarization VAP".  The user will need to check the long_name in the individual data files to 
determine if the long_name is actually "Cloud mask from depolarization VAP" or "Cloud 
mask from ASR VAP".  In addition, the data type of the cmask field changes depending on the 
source.  If the long_name is "Cloud mask from depolarization VAP", the data type is 
"int".  If the long_name of the cmask field is "Cloud mask from ASR VAP", the data type if 
"float".
Suggestions: 
Users should be aware that the temperature field is always "Temperature from 

twpsondewnpnC3.b1" and the pressure field is always "Pressure from twpsondewnpnC3.b1".  In 
addition, the user will need to check the long_name of the cmask field in each data file to 
determine if the field was derived from the depolarization VAP or ASR VAP.  The user also 
should be aware that the data type of the cmask field will be integer if the field was 
derived from the depolarization VAP, and float if the cmask field was derived from the ASR VAP.
Measurements:twp10rlprofbe1newsC3.s1:
  • pressure
  • temperature
  • cmask
more
twp10rlprofbe1newsC3.c1:
  • temperature
  • cmask
  • pressure
more

Close this window