SGP/EBBR/E12 - Sensible and Latent Heat Fluxes and Net Radiation Incorrect
DataStreams:sgp30ebbrE12.b1
Description:
Sensible and latent heat fluxes were incorrect because the measured net radiation was too 
small.
Suggestions: 
The SIRS net radiation could be used to re-calculate sensible and latent heat fluxes 

by apportioning the difference between SIRS and EBBR net radiation to the sensible and 
latent heat fluxes in the same percentage that each is of the total of the two fluxes.
Measurements:sgp30ebbrE12.b1:
  • net_radiation
  • sensible_heat_flux
  • latent_heat_flux