Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
08/01/2000 | 0000 | 08/31/2000 | 2359 | Does not affect quality |
Subject: | SGP/OKM - Overview of Automated Data Quality - August 2000 |
DataStreams: | sgp05okmX1.b1, sgp15okmX1.b1, sgp15okmX1.a1, sgp05okmX1.a1 |
Description: | Below is an overview from Chris Fiebrich, the Mesonet QA manager of the automated quality assurance results for the August 2000 Oklahoma Mesonet data. TAIR Current: None Added: None Resolved: None RELH Current: #5084 WAUR Sensor found to be 7% high during Spring Pass 2000 comparison Added: None Resolved: #5140 MAYR Replaced sensor exceeding 103% WDIR Current: None Added: None Resolved: None WSPD Current: None Added: None Resolved: #5158 MADI Replaced sensor due to noisy bearings #5195 SALL Replaced sensor due to noisy bearings PRES Current: None Added: None Resolved: #5086 RETR Replaced sensor with high bias SRAD Current: #5070 HOOK Sensor found to be 6.5% high during Spring Pass 2000 comparison #5072 KETC Monthly QA indicates 5-10% high bias #5091 WIST Sensor found to be 5.5% low during Spring Pass 2000 comparison #5097 BESS Sensor found to be 10% high during Spring Pass 2000 comparison #5099 MEDF Sensor found to be 8% low during Spring Pass 2000 comparison #5101 WALT Sensor found to be 10% low during Spring Pass 2000 comparison #5111 GOOD Sensor found to be 6.7% high during Spring Pass 2000 comparison #5115 FREE Sensor found to be 6% high during Spring Pass 2000 comparison #5159 FAIR Sensor stuck at 0 Added: None Resolved: #5079 WASH Replaced sensor with high bias RAIN Current: #5208 MTHE Gauge double-tipping on one side Added: None Resolved: #5078 BURN Removed spider web that was clogging gauge #5098 BESS Replaced gauge that was found to be double-tipping on one side of bucket during Spring Pass 2000 test #5162 TAHL Replaced gauge that was found to be double-tipping #5183 CHAN Replaced suspect switch #5184 BOWL Replaced switch found to be double-tipping #5185 TIPT Replaced gauge despite 4 success- ful drip tests because site has had longest dry period #5188 VINI Replaced gauge found to be double-tipping on one side #5202 SKIA Replaced gauge found to double- tip occasionally TA9M Current: None Added: None Resolved: None WS2M Current: None Added: None Resolved: #5141 DURA Replaced sensor reporting constant 0 m/s TS10 Current: #5178 MADI Sensor sporadically reports +5 C offset #5199 DURA Sensor reporting sporadically and 8 C warm Added: None Resolved: None TB10 Current: None Added: None Resolved: #5179 SALL Replaced bad sensor #5200 GRA2 Repaired cracked ground over bare plot TS05 Current: #5194 FAIR Sensor has 5 C cool bias since lightning strike Added: None Resolved: None TB05 Current: #5187 DURA Sensor stuck at -273.1 C Added: None Resolved: #5201 GRA2 Repaired cracked ground over bare plot TS30 Current: None Added: None Resolved: None ---------------------------------------------------------------- ARS QA REPORT ---------------------------------------------------------------- TAIR Current: #5180 A182 Sensor found to be 2.5 C warm during ARS pass Added: None Resolved: None RELH Current: None Added: None Resolved: None SRAD Current: None Added: None Resolved: None RAIN Current: None Added: None Resolved: None TS05 Current: #5181 A132 Monthly QA indicates 4 C warm bias during all times of day #5203 A167 Sensor reporting erratically and has 10 C warm bias Added: None Resolved: None TS10 Current: #5182 A167 Monthly QA indicates 4 C warm bias during all times of day Added: None Resolved: None TS15 Current: None Added: None Resolved: None TS30 Current: #5157 A165 Reporting erratic observations Added: None Resolved: None ======================================================================== LEGEND TAIR Air Temperature measured at 1.5 meters RELH Relative Humidity measured at 1.5 meters WDIR Wind Direction measured at 10 meters WSPD Wind Speed measured at 10 meters PRES Pressure SRAD Incident Solar Radiation RAIN Rainfall TA9M Air Temperature measured at 9 meters WS2M Wind Speed measured at 2 meters TS10 Soil Temperature measured at 10 cm under native sod TB10 Soil Temperature measured at 10 cm under bare soil TS05 Soil Temperature measured at 5 cm under native sod TB05 Soil Temperature measured at 5 cm under bare soil TS15 Soil Temperature measured at 15 cm under native sod TS30 Soil Temperature measured at 30 cm under native sod ======================================================================= |
Suggestions: | |
Measurements: | sgp05okmX1.b1: more
sgp05okmX1.a1: more sgp15okmX1.b1: more sgp15okmX1.a1: more |