DQRID : D011221.6
Start DateStart TimeEnd DateEnd Time Data Quality Metric
05/15/2001231512/14/20012356Suspect
more
Subject:
SGP/EBBR/E9 - Reprocess: E9 EBBR Soil Temperature #5 Intermittently Incorrect
DataStreams:sgp30ebbrE9.b1, sgp15ebbrE9.b1
Description:
Soil moisture probe #5 in the recalibrated unit installed
on 5/11/01 has not been working all of the time.  At times
the measurement has been very large and incorrect.  The
indicated measurements are incorrect at those times.  The
data must be inspected to determine the times that 
have incorrect data.  The sensible and latent heat fluxes can
be recalculated by using soil sets 1, 2, 3, and 4 only in a 
recalculation of the energy budget.
Suggestions: 
Inspect data for times of incorrect data.  Soil temperatures above 35 C or below -10 

C are not likely at E9
Measurements:sgp30ebbrE9.b1:
  • latent_heat_flux
  • soil_temp_5
  • surface_soil_heat_flux_avg
  • surface_soil_heat_flux_5
  • sensible_heat_flux
  • energy_storage_change_5
more
sgp15ebbrE9.b1:
  • soil_temp_5_rr
more

Close this window