DQRID : D031117.2
Start DateStart TimeEnd DateEnd Time Data Quality Metric
11/14/2003211511/26/20031600Incorrect
more
Subject:
SGP/EBBR/E19 - AEM Stuck In One Position, Surface Fluxes Incorrect
DataStreams:sgp15ebbrE19.b1, sgp30ebbrE19.b1, sgp5ebbrE19.b1
Description:
The AEM home 15 and 30 outputs were both 40 mv
because the AEM was not exchanging.

Sensible and Latent Heat Fluxes are therefore
incorrect.
Suggestions: 
There is no workaround for this problem.
Measurements:sgp30ebbrE19.b1:
  • vapor_pressure_top
  • vapor_pressure_bottom
  • temp_trh_bottom
  • rh_top_fraction
  • rh_bottom_fraction
  • temp_air_top
  • bowen_ratio
  • temp_trh_top
  • temp_air_bottom
  • sensible_heat_flux
  • latent_heat_flux
more
sgp15ebbrE19.b1:
  • temp_air_left
  • temp_air_right
  • temp_trh_right_rr
  • temp_trh_left_rr
more
sgp5ebbrE19.b1:
  • vapor_pressure_bottom
  • temp_trh_top
  • rh_bottom_fraction
  • temp_air_bottom
  • temp_air_top
  • rh_top_fraction
  • vapor_pressure_top
  • temp_trh_bottom
more

Close this window