DQRID : D080318.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
03/18/2008100003/27/20081930Incorrect
more
Subject:
SGP/EBBR/E13 - Wind direction failure
DataStreams:sgp5ebbrE13.b1, sgp30ebbrE13.b1, sgp15ebbrE13.b1
Description:
The EBBR wind direction was stuck at 135 degrees; this reading indicates a failure of the 
sensor electronics.
Suggestions: 
Use the co-located SMOS wind direction instead.
Measurements:sgp15ebbrE13.b1:
  • wdir_vec_mean_mv
more
sgp5ebbrE13.b1:
  • wspd_vec_mean
  • wdir_vec_std
  • wdir_vec_mean
more
sgp30ebbrE13.b1:
  • wdir_vec_std
  • wdir_vec_mean
  • wspd_vec_mean
more

Close this window