DQRID : D110926.1
Start DateStart TimeEnd DateEnd Time Data Quality Metric
02/20/2011130004/28/20111930Incorrect
more
Subject:
SBS/GNDRAD/M1 - IRT bias
DataStreams:sbsgndrad60sM1.b1
Description:
The IRT was indicating lower surface temperatures than the PIR. It is unknown how the 
problem was corrected, but there was a concurrent increase in logger voltage of 0.02 V.
Suggestions: 
Measurements:sbsgndrad60sM1.b1:
  • sfc_ir_temp_min
  • sfc_ir_temp_max
  • sfc_ir_temp
more