Subject:
TWP/MERGESONDE/C2 - Reprocess: Suspect rh_scaled values
DataStreams:twpmergesonde1maceC2.c1
Description:
MERGESONDE sometimes uses bad or questionable precipitable water vapor data to scale the 
relative humidity profiles provided by the rh_scaled field. In addition, this bad input 
data is not properly indicated by the vapor_source or qc_rh_scaled fields. This problem 
appears to typically occur when there is moisture impacting the microwave radiometer causing 
large spikes in brightness temperatures. During these periods the rh_scaled values are 
often saturated at 101% for much of the profile.
Suggestions: 
Take care when using the data from the rh_scaled field, particularly during 

precipitation events. Check the stat2_pwv field from the MWRRET VAP, and/or the vap field from 
the MWR instrument for problems before using these data.