08/19/1994 | 1900 | 08/24/1994 | 1600 | Incorrect |
Subject: | SGP/EBBR/E8 - Battery Voltage Drop |
DataStreams: | sgp30ebbrE8.b1, sgp15ebbrE8.b1, sgp5ebbrE8.b1 |
Description: | Sometime after 0000 GMT on August 19, 1994 the cable from the solar panel to the EBBR battery was broken, presumably the result of severe weather that was in the area. The result was that the battery could not be charged by the solar panel, leading to a gradual reduction in battery voltage. By 1730 GMT on the 19th, the battery voltage had dropped to 10.8 volts and at about 1905 GMT had dropped too low to power the AEM. Some thirty minute data after 1900 GMT is therefore incorrect. By 2000 GMT the voltage had dropped to 10.7 volts and was too low to properly power the barometric pressure sensor (it's output dropped off from then on). At 1530 GMT on August 24, 1994 the solar panel connection to the battery was reestablished and normal data acquisition resumed at 1600 GMT. The last data file to be produced was apparently 0000 GMT (15 minute file) on 20 August. In an apparently related incident, soil temperature #3 skyrocketed in output beginning at about 1815 GMT; the cause for this is unknown, but is probably a result of the inability of the CR10 data logger to correctly measure the sensor resistance. By 1900 GMT this situation had caused elevated average soil heat flux, which in turn affected calculated e and h. Data fields that are incorrect for the time period listed, follow: 5 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, vp_bot 15 minute: rr_thum_r, rr_thum_l, mv_hum_r, mv_hum_l, tair_r, tair_l 30 minute: tair_top, tair_bot, thum_top, thum_bot, hum_top, hum_bot, vp_top, vp_bot, bowen, e, h |
Suggestions: | |
Measurements: | sgp5ebbrE8.b1: more
sgp15ebbrE8.b1: more sgp30ebbrE8.b1: more |