DQRID : D951113.4
Start DateStart TimeEnd DateEnd Time Data Quality Metric
11/01/1995154511/01/19951845Incorrect
more
Subject:
SGP/EBBR/E26 - Right Tair Offscale
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
Description:
On 1 November 1995 at E26, Cement, OK EBBR the right thermocouple output
went offscale for a few hours.  The cause for this is unknown and the
sensor recovered fully.  Incorrect data for the period above includes:

5 minute:   tair_top, tair_bot

15 minute:  tair_r, tair_l

30 minute:  tair_top, tair_bot, bowen, h, e
Suggestions: 
Measurements:sgp5ebbrE26.b1:
  • temp_air_bottom
  • temp_air_top
more
sgp15ebbrE26.b1:
  • temp_air_left
  • temp_air_right
more
sgp30ebbrE26.b1:
  • bowen_ratio
  • temp_air_top
  • sensible_heat_flux
  • latent_heat_flux
  • temp_air_bottom
more

Close this window