Description: | On 29 November 1995, the Gel Cell battery for the E4 EBBR at Plevna, KS
was replaced with a lead acid battery. Gel Cells do not charge or keep
a charge in cold weather as well as lead acid batteries. Some data loss
and incorrect data resulted. Of the period listed above, the data that is
missing and incorrect is listed below. Some data for the incorrect periods
is incorrect (sensible and latent heat fluxes), while other data values may be
correct (for example: wind speed and direction, soil moisture, etc.) It
may be wise to not use any of the 2030 GMT 5, 15, and 30 minute data.
5 minute: missing 1745-2010 GMT
incorrect 2015-2030 GMT
15 minute: missing 1745-2000 GMT
incorrect 2015-2030 GMT
30 minute: missing 1800-2000 GMT
incorrect 2030 GMT |