Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
04/23/1996 | 1500 | 04/23/1996 | 2115 | Incorrect |
Subject: | SGP/EBBR/E26 - Right Air Temp Malfunction |
DataStreams: | sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1 |
Description: | The right air temperature probe malfunctioned and produced incorrect data during the period of time indicated above. The probe (S/N 92013) was replaced by Site Operations on 23 April 1996 at 2115 GMT with S/N 92002. The malfunction of the right air temperature probe results in incorrect Bowen ratio, sensible heat flux, and latent heat flux during the period indicated. The data values that are affected are: 5 minute: tair_top, tair_bot 15 minute: tair_r (1515-2115 GMT values) 30 minute: tair_top, tair_bot, bowen, e, and h (1530-2130 GMT values) |
Suggestions: | |
Measurements: | sgp5ebbrE26.b1: more
sgp15ebbrE26.b1: more sgp30ebbrE26.b1: more |