Subject:
SGP/EBBR/E26 - 3-month check
DataStreams:sgp30ebbrE26.b1, sgp15ebbrE26.b1, sgp5ebbrE26.b1
Description:
During EBBR 3 month checks the Automatic Exchange Mechanism is disabled
(reflected by home signals near zero) so that the two aspirator units can be
placed at the same height.  The measurements during this period, at least,
do not produce correct outputs of bowen ratio (bowen), sensible heat flux (h),
or latent heat flux (e), nor do the air temperature and relative humidity
measurements indicate gradients.  Checks performed before or after the AEM
is disabled also lead to some incorrect data.  The period of incorrect
data for the EBBR is listed; data times affected do not include the
beginning time and do include the ending time (data files are denoted by
the end time).
Suggestions: 
Measurements:sgp5ebbrE26.b1:
  • vapor_pressure_bottom
  • vapor_pressure_top
  • temp_trh_bottom
  • rh_top_fraction
  • temp_trh_top
  • temp_air_bottom
  • rh_bottom_fraction
  • temp_air_top
more
sgp15ebbrE26.b1:
  • temp_trh_right_rr
  • temp_air_right
  • temp_air_left
  • rh_left_mv
  • temp_trh_left_rr
  • rh_right_mv
more
sgp30ebbrE26.b1:
  • bowen_ratio
  • rh_bottom_fraction
  • temp_trh_top
  • temp_trh_bottom
  • rh_top_fraction
  • temp_air_top
  • latent_heat_flux
  • temp_air_bottom
  • vapor_pressure_top
  • sensible_heat_flux
  • vapor_pressure_bottom
more