Start Date | Start Time | End Date | End Time | Data Quality Metric |
---|---|---|---|---|
11/25/1998 | 1735 | 12/29/1998 | 1630 | Incorrect |
Subject: | SGP/EBBR/E20 - Data Incorrect |
DataStreams: | sgp15ebbrE20.b1, sgp5ebbrE20.00, sgp30ebbrE20.b1, sgp5ebbrE20.b1 |
Description: | Version 6 of the CR10 program was installed during this period instead of version 7 (the initial version 7 program did not work). The calibrations and coefficients in version 6 were incorrect; therefore all data during this period is of questionable quality and e and h are clearly incorrect. The correct version 7 program was installed on 29 Dec 1998. |
Suggestions: | |
Measurements: | sgp30ebbrE20.b1: more
sgp15ebbrE20.b1: more sgp5ebbrE20.00: more sgp5ebbrE20.b1: more |