DQRID : D050323.2
Start DateStart TimeEnd DateEnd Time
03/06/2005140003/16/20051900
more
Subject:
SGP/EBBR/E22 - Net Radiation Too Low - Top Dome Broken
DataStreams:sgp30ebbrE22.b1, sgp15ebbrE22.b1, sgp5ebbrE22.b1
Description:
Net radiation values were too low because of a broken top dome.
Suggestions: 
Measurements:sgp15ebbrE22.b1:
  • Net radiation (mV)(net_radiation_mv)
more
sgp5ebbrE22.b1:
  • Net radiation(net_radiation)
more
sgp30ebbrE22.b1:
  • Surface sensible heat flux(sensible_heat_flux)
  • Surface latent heat flux(latent_heat_flux)
  • Net radiation(net_radiation)
more

Close this window